ATEX Explosion Protected Weight Indicator INDATEX2GDF

INDATEX2GD Weegindicator
INDATEX2GD Weegindicator

logo_atex_60pxVersatile weight indicator, ATEX version.  For dosage in Zone 1 & 21. 

CE verifiable. Clearly readable LCD-display in stainless steel housing, protection class IP68. Suitable for application in ATEX hazardous area.

See further under the tab Product information.

 

  1. Type: INDATEX2GDF Version: Verifiable Particularity: with firmware for dosage systems Price: On application

ATEX Explosion Protected Weight Indicator INDATEX 2GDF

  • Suitable for use in hazardous areas Zone 1 & 21, Protection according to:
    • ATEX II 2 (2) G Ex ib [ib Gb] IIC T4 Gb for gas, zone 1
    • ATEX II 2 (2) D Ex tb [ib Db] IIIC T197˚C IP65 Db for dust, zone 2
  • Ideal for creating automatic or semiautomatic dosage system in loading or in unloading, or multiproduct dosages and mixtures.
  • CE verifiable
  • waterproof keyboard with 17 keys
  • LCD display with 6 25-mm high contrast digits, clearly visible even in poor lighting conditions and with low temperatures, and with symbols for showing the active functions
  • stainless steel housing, protection class IP68, dim. 264 x 174 x 115 mm
  • display resolution up to 10000e or multi range 2 x 3000e (0.3 μV / d in CE-verified application)
  • max. 1,000,000 visible parts in display for internal use and with an internal resolution of 3,000,000 parts
  • management of a weighing system from 1 to 4 channels (cells) with digital equalization.
  • memory back-up for recording dosage data in case it’s accidentally turned off.
  • printing the dosage and consumption data, in safe zone through fiber optic.
  • number of connectable load cells: 4 (350 Ω)
  • main certificate: OIML R76
  • bidirectional glass fiber port (for connection to printer, PC or PLC in the safe zone)
  • 4 barriered logic digital outputs, with programmable function, for dosage system management, connectable to other intrinsic safety devices in a hazardous area.
  • 4 inputs with functions dependents on the selected dosage function
  • power supply through external power adapter with 230 VAC input

Options: i.a.

  • wall bracket, stainless steel – for mounting the indicator on the wall
  • painted steel pole – for mounting the indicator
  • stainless steel pole – for mounting the indicator
  • built-in ATEX RS-485 interface
  • optical fiberglass / RS-232 converter
  • optical fiberglass / RS-232 converter for DIN Rail
  • optical fiberglass / USB converter
  • RS485 active barrier – for connection to external devices in safe zone

More options, to be used only in safe zone: