Passive safety zener barriers ZBX

zenerdiodes_atex_zbx
zenerdiodes_atex_zbx

logo_atex_35px Kit of 3 intrinsic safety zener diodes, for connection of devices in ATEX hazardous area to devices in safe areas.

See further under the tab Product information.

Passive safety zener barriers ZBX

  • suitable for mounting on a panel board on an omega bar in a safe area, or in a hazardous-proof case, for intrinsic safety weighing systems in hazardous area
  • logo_atex_35pxATEX protection class II(1) GD [EEX ia] IIC (-20°C = Ta = +60°C). ATEX, certificate and declaration of conformity available on application
  • juncture up to 4 load cells of 350 Ω each
  • single channel properties:

    Fuse
    :
    Uo:
    Io:
    Po:
    Co:
    Lo:
    L/R:
    Rmin:
    For output:
    50 mA
    8.7 Vdc
    25 mA
    0,05 W
    4,9 µF
    57 mH
    613 µH/Ω
    352,8 Ω
    For sense:
    50 mA
    8.7 Vdc
    25 mA
    0,05 W
    4,9 µF
    57 mH
    613 µH/Ω
    352,8 Ω
    For input:
    100 mA
    12 Vdc
    164 mA
    0,49 W
    1,41 µF
    1,38 mH
    75 µH/Ω
    73,5 Ω